Sphere of application
KNBL1-32 series leakage breaker ELCB is suitable for the leakage protection of the line of A and S 50/60Hz, rated voltage single phase 240V, rated current up to 32A. When there is human electricity shock or if the leakage current of the line exceeds the prescribed value, it will automatically cut off the power within 0.1s to protect human safety and prevent the accident due to the current leakage.
KNBL1-32 series Earth Leakage Circuit Breaker can protect against overload and short-circuit. It can be used to protect the line from being overloaded and short-circuited as well as infre-quent changeover of the line in normal situation. Leakage Circuit Breaker It complies with standard of IEC/EN61009-1 and GB16917.1.
Basic specification and main parameters ELCB
KNBL1-32 series leakage breaker is suitable for the leakage protection of the line of AC 50/60Hz, rated voltage single phase 240V, rated
current up to 63A. When there is human electricity shock or if the leakage current of the line exceeds the prescribed value, it will automatically cut
off the power within 0.1s to protect human safety and prevent the accident due to the current leakage. KNLE1-32 series leakage breaker can protect against overload and short-circuit. It can be used to protect the line from being overloaded and
short-circuited as well as infrequent changeover of the line in normal situation. It complies with standard of IEC/EN61009-1 and GB16917.
Earth Leakage Circuit Breaker
Leakage Circuit Breaker
ELCB
Technique parameter:
Frame class | 32A |
Rated working voltage | 240/415V |
Rated frequency | 50/60Hz |
Rated working current | 10,16,20,25,32A |
Rated residual operating current | 0.03A |
Rated residual un-operating current | 0.015A |
Sensibility | AC Type,A Type |
Maximum operating time | In t≤0.1s , 5In t≤0.04 |
Instant release type | C type |
Limiting value of un-operating current | 6In |
Rated limiting short-circuit current | 3000A |
Pole number | 1P+N |
Mechanical life | 8000 |
Electric life | 4000 |