Company Details
Wenzhou Korlen Electric Appliances Co., Ltd.
Unit Price: | USD 1 / Bag/Bags |
---|---|
Payment Type: | L/C,T/T,D/P,Paypal |
Min. Order: | 1 Bag/Bags |
Model No.: KNLE1-63
Brand: Korlen
Breaking Capacity: Low Voltage Circuit Breakers
Operation: Manual Type
Speed: Normal Type Circuit Breaker
Arc-extinguishing Medium: Air
Installation: Fixed
Structure: Elcb
Poles Number: 2
Type: Circuit Breaker
Function: Conventional Circuit Breaker
Certification: Ce
Release Type: C
Rated Working Voltage: 240v
Frame: 32a
Rated Worling Current: 6;10;16;20;25;32a
Making And Breaking Capacity: 6000a
Packaging: carton
Productivity: 2000000pcs/month
Transportation: Ocean,Land,Air
Place of Origin: Wenzhou; Zhejiang; China
Supply Ability: 2000000pcs/month
Certificate: CE,CB;VDE;
HS Code: 8536200000
Port: Ningbo,ShangHai
Payment Type: L/C,T/T,D/P,Paypal
KNLE1-63 series leakage breaker is suitable for the leakage protection of the line of AC 50/60Hz, rated voltage single phase 240V, three
phase 240/415V and below, rated current up to 63A. When there is human electricity shock or if the leakage current of the line exceeds the prescribed
value, it will automatically cut off the power within 0.1s to protect human safety and prevent the accident due to the current leakage. KNLE1-32 series leakage breaker can protect against overload and short-circuit. It can be used to protect the line from being overloaded and
short-circuited as well as infrequent changeover of the line in normal situation. It complies with standard of IEC/EN61009-1 and GB16917.1.2. Sphere of applicati
As for household appliances, refrigerators, washing machines etc which people often contact, using Residual Current Circuit Breaker to protect human safety and prevent the accident due to the current leakage. Earth Leakage Circuit Breaker
ELCB is earth Leakage Circuit Breaker, mainly for AC,A and S 50/60Hz, rated voltage 230V(single phase)/400V(three phases), rated current up to 100A distribution network, used to prevent fire danger due to the damage of equipment insulation caused by the grounding fault current. It also can be used to protect the line from being overloaded and short-circuited as well as infrequent changeover of the line in normal situation.
Earth Leakage Circuit Breaker
Leakage Circuit Breaker
ELCB
Residual Current Circuit Breaker
Residual Current Circuit Breaker With Over Load Protection
Sequence NO. | Test Release current /In | Start state | Tripping time | Expected result Not tripping Tripping | |
1 | C 1.13In | Cold state | t≤1h | ||
2 | C 1.45In | Start right after the serial NO. 1 test | t<1h | ||
3 | C | 2.55In | Cold state | 1s Tripping | |
4 | C | 5In | Cold state | t≤0.1s | Not tripping |
5 | C 10In | Cold state | t<0.1s | Tripping |
Product Categories : Residual Current Circuit Breaker With Over Load Protection > KNLE1-63 Residual Current Circuit Breaker With Over Load Protection