Model No.: KNL5-63
Brand: KORLEN / YOUTS
Breaking Capacity: Low Voltage Circuit Breakers
Operation: Electric Type
Speed: High-Speed Circuit Breaker
Arc-extinguishing Medium: Air
Installation: Fixed
Structure: Elcb
Poles Number: 2
Type: Circuit Breaker
Function: Circuit-Breaker Failure Protection
Certification: Iso9001-2000
Rated Frequency: 50/60hz
Rated Working Voltage: 240v
Rated Limiting Short-circuit Current: 6000a
Electric Life: 4000
Rated Working Current: 6 10 16 20 25 32 40 50 63a
Rated Residual Operating Current: 10ma 30ma 100ma 300ma
Mechanical Life: 20000
Sensibility: A Type /Ac Type
Pole Number: 1p + N/3p+N
Packaging: carton
Productivity: 1200000/MONTH
Transportation: Ocean
Place of Origin: WENZHOU ZHEJAING CHINA
Supply Ability: 1200000/MONTH
Certificate: ISO9001/ISO14001
HS Code: 8536200000
Port: Ningbo,Shanghai
Payment Type: T/T
Incoterm: FOB
KNL5-63 series Residual Current Circuit Breaker (without over-current protection) is suitable for the line of A and S 50/60Hz, voltage 240V(2pole)/415V(4pole), rated current up to 100A. When there is human electricity shock or if the leakage current of the line exceeds the prescribed value, it will cut off the power rapidly to protect human safety and prevent the accident due to the current leakage. It can be used as infrequent changeover of the line in normal situation. It is applicable to industrial site, commercial site, tall building and civil house.
It complies with standard of IEC/EN61008.1 and GB16916.1.
Each phase of conductor at the RCCB passes through the zero-sequence current transformer, and the secondary side of coil connects with the electromagnetic tripper. Under normal condition, the vector sum of each phase of current passing through zero-sequence current transformer is zero. The flux of the zero-sequence current transformer is zero. And the secondary output voltage is zero and the Circuit Breaker doesn't zero, and the zero-sequence current transformer would produce the magnetic flux, and the secondary side of coil would output the voltage. Once the leak current increases to drive the output voltage at the secondary side to grow to certain level, the electromagnetic release would activate to drive the operation mechanism to act to break the contact that connects the power, finally to realize the leak protection.
Residual Current Circuit Breaker
Ac Residual Current Circuit Breaker
Miniature Residual Current Circuit Breaker
Residual Current Electrical Circuit Breaker
Frame class | 63A |
Rated working voltage | 240/415V |
Rated frequency | 50/60Hz |
Rated working current | 16,20,25,32,40,50,63,80,100,125A |
Rated residual operating current | 0.1,0.3,0.5A |
Rated residual un-operating current | 0.05,0.15,0.25A |
Sensibility | A Type,AC Type,S Type |
Maximum operating time | IΔn t≤0.1s , 5IΔn t≤0.04 |
Rated making and breaking capacity | In≤50A 500A,In=63A 630A , In>63A 1500A |
Limiting value of un-operating current | 6In |
Rated limiting short-circuit current | 10000A |
Pole number | 2,4P |
Mechanical life | 10000 |
Electric life | 4000 |
Product Categories : Residual Current Circuit Breaker > KNL5-63 Residual Current Circuit Breaker